Equipment: concrete scanner ZBL-R800 rebar locator
Equipment Type: Instrument -> Test Instrument
Unit Type: sets
Technical Parameters: Tested area: 234m2
Post Time: 2017-07-17
Main Features: 1.Multi function rebar detector = rebar locator + rebar corrosion detector; an economical and convenient device. 2.This model features the world’s first wireless onsite data transfer function for such a device and remote management is also available 3.Data can be stored on a usb-thumb drive, great for field work 4.This device can generate rebar distribution map and rebar corrosion potential contour graph. 5.Powerful professional analysis-process software allows for the automatic generation of test reports.
Usage: Built-in chargeable lithium battery
Description: ZBL R800 concrete reinforcement detector Rebar Detector ZBL R800 Multi-function Concrete Rebar Locator/Detector 1.Multi function rebar detector = rebar locator + rebar corrosion detector; an economical and convenient device. 2.This model features the world’s first wireless onsite data transfer function for such a device and remote management is also available 3.Data can be stored on a usb-thumb drive, great for field work 4.This device can generate rebar distribution map and rebar corrosion potential contour graph. 5.Powerful professional analysis-process software allows for the automatic generation of test reports. Dalian Taijia Technology Co., Ltd Contact us: market@tmeasurement.com 86-411-39685079 86-411-86737519 Introduction Preface ZBL-R800 Multifunctional Rebar Detector is a portable integrative and multifunctional one combines the functions of both scanner for rebar test and detector for rebar rust test. Functions Identify rebar location direction and distribution. Double function of rebar and rust test Test the thickness of concrete cover. Test rebar diameter. Qualify the thickness of concrete cover automatically. Test data storage check and transmission. Single-electrode testing of concrete rebar corrosion. Double-electrode testing of concrete rebar corrosion. Divide rebar corrosion in maximal 10 gray shades or color graphs. Analyze professionally with Test Data Processing Software. Technology Data Sheet Applicable range Ф6mm~Ф50mm Corrosion detection method Single electrode Double electrode Protective layer thickness rang(mm) First range Second range Measuring range ±1000mV 0~1000 mV 3~98 3~196 Accuracy ±1mV ±1mV Maximum allowed error for protective layer ±1 mm 6~56 3~79 Tested points Interval X 0~100 adjustable 20 fixed ±2 mm 57~69 80~119 Tested points interval Y 0~100 adjustable 0~100 adjustable ±4 mm 70~98 120~196 Power Built-in chargeable lithium battery Maximum allowed error ±1 rebar standard level Battery Time >38 hours Data transmission wireless transmission Dimensions 212mm´134mm´50mm USB port thumb drive storage available Weight 0.9kg Packaging List ZBL-R800 Carrying case 1 ZBL-R800 Detector 1 ZBL-R800 Battery Charger 1 DC 8.4V/0.5A Rebar Sensor 1 SET200A Copper Sulfate Electrode 3 SCH01C Double-electrode handle 1 C3-DP20 Electrode Cap 1 Art NO.8000 Signal Wire 1 Double-electrode Wire 1 Copper Sulfate Crystal 1 U-disk 1 Rebar Sensor 1 SET180C Certification 1 Packing List 1 Safety Instructions For a better usage please read operation manual carefully before using the instrument.  Requirements for working environment:  Environmental temperature: 0℃~40℃;  Relative humidity :< 90%RH;  Long time sunlight perpendicular incidence is avoided.  Anti-corrosion: when used under damp dusty and full of corrosive gas conditions protective measures are necessary.  Requirements for storage environment:  Environmental temperature:-20℃~+60℃.  Relative humidity: < 90%RH;  Out of use please place instrument into package store in a ventilated cool and dry place Long time sunlight perpendicular incidence is avoided.  If long time out of use please charge and start up for a check regularly.  Avoid water.  Avoid usage under strong magnetic field such as the nearby of large electromagnet or transformer.  Shock-proof: During the process of usage or handling avoid severe vibration or shock. Maintenance  Power supply Instrument charges with inside specific chargeable lithium battery after full charge it can work last for nearly 26 hours. When used please pay attention to left of electricity. If lack of electricity close instrument quickly and charge in time. Or it can lead to lose of testing data as a result of sudden blackout even damage to instrument. Avoid using other batteries or power supplies.  Charge When charged plug the power supply into AC220±10%V socket and plug charger into the instrument’s power supply .when the charge indicator is red it is charging to the inside battery. When turning to yellow it is completed. At that time unplug the charger in time lest overcharge affects the battery service life. Attention: To guarantee full charge please charge 6-8 hours consecutively at the same time avoid charge under the environment of over 60℃. Long time out of use charged battery will discharge and lead to decrease of electricity. Recharge before usage. While charged a common phenomenon is instrument and charger will be heated in some extent. Good ventilation is necessary for heat dissipation. Attention: Avoid charge with other power adapters or it will cause damage to instrument.  Rechargeable battery When battery is near the end of service life after frequent charges and discharges if the battery works abnormally (cannot charge with electricity cannot charge full or short time is used after full charge) it is probable that rechargeable battery has been damaged or reaches its end. At that time please contact with our company change a new one. Avoid short circuit of battery or approaching high source temperature.  Every time when used proper cleaning for host and sensors etc is necessary against water or dirty into plug in or instrument or it will lead to low performance even damage of instrument. Attention: Avoid placing instrument and fittings in water or cleaning with wet cloth. Avoid scrubbing instrument and fittings with organic solvent. Please wipe host and socket with clean and soft dry cloth Responsibilities The instrument is sophisticated testing equipment. When user has one of the following actions or the other man-made destruction the company does not undertake related responsibilities:  Violate the above requirements for working and storage environment;  Improper operation;  Open case arbitrarily or dissemble any components without permission;  Man-made or accident-caused severe damage to instrument.
Inquiry
Recipient: olivia Company: Dalian Taijia Technology Co., Ltd.
Title: *    
Content: *
Contact
Name: * Company: *
Tel: * E-Mail: *
Fax: WebSite:
  
Copyright©Chemamde Contact us Tel:086-411-39685079 Fax:086-411-39685079